Sign In | Join Free | My isp.org.cn
China Changzhou Victory Technology Co., Ltd logo
Changzhou Victory Technology Co., Ltd
Changzhou Victory Technology Co., Ltd
Verified Supplier

2 Years

Home > Thermocouple Compensating Wire >

Bright Thermocouple Extension Wire Fiberglass Insulation Compensation Cable

Changzhou Victory Technology Co., Ltd
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

Bright Thermocouple Extension Wire Fiberglass Insulation Compensation Cable

Brand Name : Victory

Model Number : K,N,E,J,T,B,R,S Types

Certification : CE,ROHS,ISO 9001

Place of Origin : China

MOQ : 5

Payment Terms : L/C, T/T, Western Union, MoneyGram

Supply Ability : 300 tons per month

Delivery Time : 5-21 days

Packaging Details : Spool package with Carton box, Coil package with polybag

Product name : Thermocouple extension wire

Color : bright

Certificate : ISO9001

Temperature range : 32 to 392F (0 to 200C)

EMF tolerance : +/- 2.2C or +/- .75%

Grade : Extension Grade NPX/NNX

Positive : Ni-cr-si

Negative : Ni-si-magnesium

other name : Nicrosil

Special Limits of Error : +/- 1.1C or 0.4%

Contact Now

Thermocouple Extension Wire is a cable designed to extend thermocouple signals and is suitable for a variety of thermocouple types, including Type K, Type N, Type E, Type J, Type T, Type B, Type R, and Type S. It plays a vital role in the field of temperature measurement and control.

The main purpose of Thermocouple Extension Wire is to transmit the thermocouple signal from the measurement point to the instrument or control system for accurate temperature measurement and monitoring. This cable uses thermocouple wires made of two different metal materials to determine the temperature value by measuring the temperature difference between the two junctions. Its special design and material selection ensure good linear characteristics and stability, and can accurately capture and transmit weak thermocouple voltage signals.

Thermocouple Extension Wire has excellent anti-interference capabilities and can effectively resist the effects of electromagnetic interference, noise and temperature changes on signals. This enables it to stably transmit reliable temperature data in industrial environments, ensuring the accuracy and reliability of temperature measurement.


Thermocouple Wire

Code Wires component of the thermocouple
+Positive leg -Negative leg
N Ni-cr-si (NP) Ni-si-magnesium (NN)
K Ni-Cr (KP) Ni-Al(Si) (KN)
E Ni-Cr (EP) Cu-Ni<constantan> (EN)
J Iron (JP) Cu-Ni<constantan> (JN)
T Copper (TP) Cu-Ni<constantan> (TN)

​Standards

ASTM ANSI IEC DIN BS NF JIS GOST
(American Society for Testing and Materials) E 230 (American National Standard Institute) MC 96.1 (European Standard by the International Electrotechnical Commission 584)-1/2/3 (Deutsche Industrie Normen) EN 60584 -1/2 (British Standards) 4937.1041, EN 60584 - 1/2 (Norme Française) EN 60584 -1/2 - NFC 42323 - NFC 42324 (Japanese Industrial Standards) C 1602 - C 1610 (Unification of the Russian Specifications) 3044

Thermocouple No. indexing Compensation wire type Usag Classification Measuring junction temperature / ℃ standard EMF value/μV Precision grade General grade
Tolerance μV Thermal EMF range μV Tolerance μV Thermal EMF range μV
SorR SC or RC G 100 646 ±30 616~676 ±60 586~706
H 100 646 - - ±60 586~706
200 1 1441 - - 1.381~1 501
K KX,KCA G -25 -968 ±40 -924~-1 012 ±80 -880~-1 056
or KCB 100 4 096 4 052~4 140 4 008~4 184
H -25 -968 ±40 -924~-1 012 ±88 -880~-1 056
100 4 096 4 052~4 140 4 008~4 184
200 8 138 8 094~8 182 8 050~8 226
N NX or NC G -25 -646 ±43 -603~-689 ±86 -560~-732
100 2 774 2 731~2 817 2 688~2 860
H -25 -646 ±43 -603~-690 ±86 -560~-732
100 2 774 2 731~2 817 2 688~2 860
200 5 913 5 870~5 956 5 827~5 999
E EX G -25 -1 432 ±81 -1 351~-1 513 ±138 -1 294~-1 570
100 6 319 6 238~ 6400 6 181~6 457
H -25 -1 432 ±81 -1 351~- 1513 ±138 -1 294~-1 570
100 6 319 6 238~6 400 6 181~6 457
200 13 421 13 340~13 502 13 283~13 559
J JX G -25 -1 239 ±62 -1 177~-1 301 ±123 -1 116~-1 362
100 5 269 5 207~5 331 5 146~5 392
H -25 -1 239 ±62 - 177~-1 301 ±123 -1 116~-1 362
100 5 269 5 207~5 331 5 146~5 392
200 10 779 10 717~10 841 10 656~10 902
T TX G -25 -940 ±30 -910~-970 ±60 -850~-1 000
100 4 279 4 249~4 309 4 189~4 339
H -25 -940 ±48 -892~-988 ±90 -850~-1 030
100 4 279 4231~4 327 4 189~4 369
200


Type N Accuracy (whichever is greater):

  • Maximum continuous operating temperature: up to 2,300F (1,260C)

  • Short term use: 2,336F (1,280C)

  • Thermocouple grade wire, -454 to 2300F (-270 to 1,260C)

  • Extension wire, 32 to 392F (0 to 200C)

Bright Thermocouple Extension Wire Fiberglass Insulation Compensation Cable Bright Thermocouple Extension Wire Fiberglass Insulation Compensation Cable


Product Tags:

Bright Thermocouple Extension Wire

      

Fiberglass Insulation Compensation Cable

      
Cheap Bright Thermocouple Extension Wire Fiberglass Insulation Compensation Cable wholesale

Bright Thermocouple Extension Wire Fiberglass Insulation Compensation Cable Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Changzhou Victory Technology Co., Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)